Twin Phase Valve for Refrigerant Gases

>Valve having two outlets, one for discharge of vapour phase and other for liquid phase (Valve inlet hole connected to liquid outlet port must be fitted with diptube).
>Lense washer between lubricated spindle and tip holder reduces friction between diaphragm and spindle assuring long wear resistance service life.
>Valve design meets design and test requirements of EN ISO 10297:2006 for maximum Test pressure (Pvt) of 50 Bar, tested and certified at BAM Berlin.
>Valves successfully tested for impact at 250J and can be used without valve protection for cylinder package mass not exceeding 69.4 kgs.
>Valve inlet hole for liquid phase threaded 3/8" BSB for dip tube fitment.

Optional :
-Outlet seal nut.
-Dip tube.
-PRV as per CGA S.1.1 with set pressure of 600 psig and flow discharge pressure of 800 psig.